Product Overview
The Bosch DS150i Series is a passive-infrared detector designed for request-to-exit (REX) applications, offering reliable motion detection for access control systems. UL 294 listed, it mounts on walls or ceilings, providing flexible coverage patterns and operational modes. Available in light gray (DS150i) and black (DS151i), it ensures seamless integration into security setups;
The Bosch DS150i Series is a range of request-to-exit (REX) detectors designed for access control systems. These passive-infrared detectors are UL 294 listed and offer flexible installation options, including wall and ceiling mounting. With adjustable coverage patterns and operational modes, they provide reliable motion detection for single or double door applications. Available in light gray (DS150i) and black (DS151i), they enhance security systems with their advanced features and durability.
The DS150i detector is specifically designed for request-to-exit (REX) applications, ensuring secure and efficient access control. It detects motion within its coverage area, signaling access control systems to grant or deny entry. Suitable for single or double door setups, it offers versatile mounting options and operational modes, making it ideal for commercial and industrial security environments. Its primary purpose is to enhance safety and streamline access management. The Bosch DS150i was introduced by Bosch Security Systems in 2004, designed to meet the growing demand for reliable access control solutions. Engineered for request-to-exit applications, it combines advanced passive-infrared technology with flexible mounting options. Over time, it has evolved to offer improved coverage patterns and operational modes, solidifying its reputation as a trusted security component in commercial and industrial settings. Its development reflects Bosch’s commitment to innovation and security excellence. The Bosch DS150i features passive-infrared detection, wall or ceiling mounting, and adjustable coverage patterns. It offers operational modes like fail-safe and fail-secure, ensuring reliable performance. The Bosch DS150i employs passive-infrared (PIR) detection technology, which senses infrared radiation emitted by moving objects. This technology ensures accurate motion detection within its coverage area, making it ideal for request-to-exit applications. Enhanced algorithms reduce false triggers, providing reliable performance in various environments. The PIR sensor operates silently and efficiently, requiring minimal maintenance while offering consistent detection accuracy. The Bosch DS150i offers versatile mounting options, enabling installation on walls or ceilings. This flexibility ensures optimal placement for coverage in various settings. The detector includes hardware for both mounting methods, and its design allows for easy adjustment to suit different environments. Whether installed on a wall or ceiling, the DS150i maintains reliable performance, ensuring accurate motion detection for access control systems. The Bosch DS150i features a wide coverage pattern, ensuring comprehensive motion detection in its area of operation. Its internal vertical pointability allows precise alignment, minimizing false triggers. Designed for single or double door applications, the detector can be mounted on walls or ceilings, adapting to various access control needs while maintaining reliable performance. The Bosch DS150i offers two operational modes: Fail Safe and Fail Secure. In Fail Safe mode, the detector ensures exit functionality remains active, while Fail Secure prioritizes security by maintaining a locked state. These modes provide flexibility for different access control requirements, ensuring reliable operation in various security environments and applications. This feature enhances the detector’s adaptability to specific system needs. The Bosch DS150i features UL 294 listing, compact dimensions, and operates in various environments. It requires minimal power and offers connectivity options for seamless integration into security systems. The Bosch DS150i is UL 294 listed, ensuring compliance with access control standards. This certification validates its reliability for request-to-exit applications, meeting strict safety and performance criteria. UL listing assures users of its adherence to industry regulations, making it a trusted choice for security installations. Compliance with UL standards enhances its credibility and suitability for commercial and residential use. The Bosch DS150i detector measures 4.5 x 2.5 x 1.5 inches, making it compact for versatile installation. Designed for indoor use, it operates effectively in temperatures ranging from 32°F to 122°F (0°C to 50°C) and humidity levels up to 95% RH. Its durable construction ensures reliability in standard environmental conditions, while its lightweight design simplifies wall or ceiling mounting. These specifications ensure optimal performance in various security setups. The Bosch DS150i requires a 12V DC power supply with a maximum current draw of 40mA. It features a 4-wire connection for straightforward installation, including power, ground, and relay outputs. The detector supports normally open (NO) and normally closed (NC) relay configurations, ensuring compatibility with various security systems. Designed for efficient operation, it maintains reliability across its specified environmental conditions, ensuring consistent performance in access control applications. The Bosch DS150i is backed by a 3-year limited warranty, ensuring coverage for manufacturing defects and faulty components. Bosch provides dedicated customer support, including 24/7 technical assistance and access to online resources like manuals and firmware updates. For extended support, users can contact Bosch’s customer service team directly or visit their official website for comprehensive guidance and troubleshooting. This ensures optimal performance and longevity of the detector. The Bosch DS150i detector is designed for easy installation, supporting both wall and ceiling mounting. Ensure proper alignment and secure fixing using the provided mounting hardware. Follow wiring guidelines carefully to avoid connectivity issues. Refer to specific subheadings for detailed mounting, wiring, and configuration steps to ensure optimal performance and reliability. The DS150i detector offers flexible mounting options for walls or ceilings. For wall mounting, align the detector with the desired coverage area and secure using screws. Ceiling installation ensures a broader coverage pattern. Use the provided trim plate for a sleek finish. Ensure the detector is level and tightly fastened to prevent movement. Follow the manual for specific torque and alignment guidelines to optimize detection accuracy and system performance. The Bosch DS150i requires 12-24 VDC power and is connected using 18 AWG wires. Ensure proper grounding to minimize interference. Connect the positive and negative terminals to the respective power sources. The detector’s relay output connects to the access control system. Use the appropriate terminals for fail-safe or fail-secure modes. Follow the manual for wiring diagrams and connectivity best practices to ensure reliable operation and system integration. Adjust the DS150i’s sensitivity and timer settings based on the environment. Use the DIP switches to configure fail-safe or fail-secure modes. Set the latch time between 0.5 to 64 seconds to match application needs. Ensure the detector is mounted at the recommended height and angle for accurate motion detection. Refer to the manual for detailed configuration steps to optimize performance and reduce false alarms in various access control scenarios. The Bosch DS150i operates in fail-safe or fail-secure modes, with selectable relay trigger options. It offers adjustable latch times from 0.5 to 64 seconds for customizable access control. The Bosch DS150i features selectable relay trigger modes, allowing users to customize the detector’s response to motion detection. These modes enhance flexibility in access control systems, ensuring compatibility with various security configurations. The relay can be set to trigger upon detection, providing a reliable signal for access control devices. This feature ensures seamless integration into existing security frameworks, offering tailored solutions for different applications. The Bosch DS150i offers adjustable latch times ranging from 0.5 to 64 seconds, providing flexibility in access control scenarios. This feature allows users to customize the duration the relay remains active after detection, ensuring precise control over door releases or alarms. The wide range of timing options accommodates various security requirements, making the DS150i versatile for different installations and applications. The Bosch DS150i may experience issues like false motion detection or connectivity problems. Check wiring, ensure clean detector optics, and verify power supply for optimal performance. To diagnose motion detection issues with the Bosch DS150i, first ensure the detector’s lens is clean and free from obstructions. Verify that the installation height and angle align with the recommended specifications. Check for sources of interference, such as nearby heating vents or electrical devices. If problems persist, review the wiring connections and ensure the power supply meets requirements. Consult the manual for detailed troubleshooting steps or contact Bosch support for assistance. To resolve connectivity and power issues with the Bosch DS150i, ensure all wiring connections are secure and free from damage. Verify the power supply matches the detector’s requirements, typically 12-24 VDC. Check for loose terminals or incorrect wiring configurations. If using a relay, confirm it is properly configured in either fail-safe or fail-secure mode. Consult the manual for detailed diagrams or contact Bosch technical support for further assistance. Regularly clean the detector’s lens and exterior with a soft cloth to ensure optimal performance. Check sensors and connections for debris or damage. Replace worn parts promptly. Avoid harsh chemicals to prevent damage. Schedule routine inspections to maintain reliability and functionality. Follow the manual’s guidelines for proper care and maintenance procedures. To ensure the Bosch DS150i operates effectively, clean its lens regularly with a soft, dry cloth. Avoid harsh chemicals or abrasive materials that could damage the sensor. Gently wipe the exterior to remove dirt or debris. Check for obstructions around the detector to maintain accurate motion detection. Perform this maintenance every 2-3 months or as needed to keep the device functioning at its best. Regular cleaning prevents false triggers and ensures reliable performance. Perform regular checkups of the Bosch DS150i to ensure optimal performance. Verify all connections and settings, and update firmware via Bosch’s software tools. Inspect the detector’s alignment and adjust if necessary. Check for any signs of wear or damage. Schedule professional maintenance annually to address issues early. Ensure compliance with the latest security standards and enhance system reliability through consistent updates and inspections. Access Bosch DS150i resources, including installation manuals, brochures, and firmware updates. Visit the Bosch Security Systems website for detailed guides, technical bulletins, and customer support. The Bosch DS150i manual is available for download in PDF format, providing detailed installation and operational instructions. Visit the official Bosch Security Systems website or authorized distributors to access the manual. Ensure you select the correct model (DS150i or DS151i) for accurate information. The manual covers setup, troubleshooting, and maintenance, essential for optimal performance and compliance with safety standards. To access software tools and firmware updates for the Bosch DS150i, visit the official Bosch Security Systems website; Navigate to the support section, where you can download the latest firmware and software tools specific to your model. Ensure you select the correct version for the DS150i or DS151i. These updates enhance functionality and ensure optimal performance. For assistance, refer to the Bosch DS150i manual or contact customer support. For assistance with the Bosch DS150i, contact Bosch customer support directly. Visit the official Bosch Security Systems website and navigate to the contact section for phone numbers, email, or live chat options. You can also call (888) 432-3232 for immediate support. The Bosch support team is available to address your queries, provide troubleshooting guidance, and assist with any technical issues related to your DS150i detector.1.2 Purpose and Applications of the DS150i Detector
1.3 Brief History and Development of the Bosch DS150i
Key Features of the Bosch DS150i
2.1 Passive-Infrared Detection Technology
2.2 Mounting Options: Wall or Ceiling Installation
2.3 Coverage Patterns and Vertical Pointability
2.4 Operational Modes: Fail Safe and Fail Secure
Technical Specifications
3.1 Certifications and Compliance (UL 294 Listing)
3.2 Dimensions and Environmental Considerations
3.3 Power Requirements and Connectivity Options
3.4 Warranty Information and Manufacturer Support
Installation Instructions
4;1 Mounting the Detector: Wall and Ceiling Options
4.2 Wiring and Connectivity Guidelines
4.3 Configuring the Detector for Optimal Performance
Operation Modes
5.1 Selectable Relay Trigger Modes
5.2 Adjustable Latch Times: 0.5 to 64 Seconds
Troubleshooting Common Issues
6.1 Diagnosing Motion Detection Problems
6.2 Resolving Connectivity and Power Issues
Maintenance and Care
7.1 Cleaning the Detector for Optimal Functionality
7.2 Regular Checkups and Updates
Additional Resources
8.1 Downloading the Bosch DS150i Manual
8.2 Accessing Software Tools and Firmware Updates
8.3 Contacting Bosch Customer Support